Bnc PB-5 Bedienungsanleitung Seite 18

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 19
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 17
18
SECTION 4
SPECIFICATIONS
Rep Rate: 2.0 Hz to 500 kHz
Width: 100 ns to 1 ms, continuously variable
Delay: 250 ns to 10 ms
Rise Time: 0.05 µs to 10 µs (10%-90%) in 8 steps
Decay Time: 0.5 µs to 1.0 ms (100%-37%) in 11 steps
Amplitude: 0.0 to 10.0 V (0 to 5 V into 50 )
Scaleable in energy units (keV)
Resolution: 155 µV
Jitter: ± 10 ppm
Attenuation: 1, 2, 5, 10, 20, 50, 100, 200, 500, 1000
Integral non-linearity: ± 15 ppm
Temperature stability: ± 5 ppm per °C from 20°C to 45°C
Pulse Type: Flat-top or tail pulse
In flat-top mode, both rise time and
decay time are adjustable. In tail mode, rise time is fixed
at 50 ns and decay time is adjustable.
Polarity: Positive/Negative
Ext. Trigger: 0 to 500 kHz, +100 mV to +10 V
Threshold is adjustable from +100 mV to +3.5 V in 0.1 V
steps.
Trigger Out: +5 V unterminated, +2.2 V into 50 , width 200 ns
Modes: Single pulse via a front panel pushbutton
Internal Rep Rate
External Trigger
External Gate with the same pulse requirements as Ext
Trig.
Internal Ramp-adjustable start and stop points: adjustable
ramp period 30-900 S, selectable number of ramp cycles,
ramp in keV or volts. Clamped baseline option to bring
the baseline to zero prior to the next pulse.
Stored Settings: Up to 9 complete configurations with recall. Also stores
parameters upon shutdown for recall when powered on.
Remote: RS232 at 9600 baud.
Seitenansicht 17
1 2 ... 13 14 15 16 17 18 19

Kommentare zu diesen Handbüchern

Keine Kommentare