
Berkeley Nucleonics Corporation 2955 Kerner Blvd., San Rafael, CA 94901
Phone: 415
-453-9955, Fax: 415
-453-9956, Em
ail:
[email protected],
Web:
www.berkeleynucleonics.com TRIangle Triangle wave output, amplitude is selectable by the :LFOutput:AMPLitude setting.
SQUare Square wave output, amplitude is fixed 2.5 V.
*RST SINE
:LFOutput:SOURce
[SOURce]:LFOutput:SOURce LFGenerator|PULM|TRIGger
[SOURce]:LFOutput:SOURce?
This command sets the low frequency generator waveform. This setting does only take effect if
:LFOutput:SOURce is set to LFGenerator.
LFGenerator This selects the low frequency generator as the function output signal.
PULM This selects the pulse modulation video out as the function output signal.
TRIGger This selects the trigger as the function output signal.
*RST LFG
Kommentare zu diesen Handbüchern